0.1毫米,端面間隙沿圓周上的不同心度允差為0.1毫米 6 7 以上為不帶底座的水泵機組的安裝方法。
對于配帶公共底座的泵,基礎與底座之間保留4~5毫米的間隙,用調(diào)整螺釘精確地調(diào)整機組并在聯(lián)軸器處對中。其安裝原則與不帶公共底座的機組相同。
l、起動:
1) a).泵或底座是否與基礎緊固:
b).聯(lián)軸器與泵機組是否校正:
c).管路是否按要求連接 d).手是否能容易地轉(zhuǎn)動轉(zhuǎn)子:
e).是否所有軸承都有良好的潤滑。
2) 2、運行:
1) 2) 3) 4) |
re
-check the alignment. Grout in the baseplate(non- shrinking mortar is highly
recommended), ensuring that no cavities remain.
5. After the eoneret
solidifed, again correct the coaxial degree in the excirele of the two
couplings, the error of the correction is not more than O.1mm, the allowable
error of the inhomo- geneous degree of the endfaee clearance along the circle
is O.3mm, Re- inspect the correct
prieision after tightening the foot nuts, finally, pour eoneret fully under the foot of the pump and the motor
except the around of the wedge shaped cushion.
6. After cheek the rotary direction of
the motor which is now in keeping with that of the pump, you can install the connecting parallel pin
of the coupling.
7. The inlet pipe and outlet
pipe should be supported by a brasket instead of the pump easing.
Above all the mentioned
methods and requirements are suitable for the pump set without common bedplate.
Samely, for the pump set
with common bedplate. Fit the pre -assembled set with foundation bolts loosely
inserted in the cut- outs in the foundation and align. There must be a 4-5cm
gap between the top of the foundation and the bottom of the baseframe.
Precisely align the set using the adjusting screws and cheek alignment on the
coupling. Others you can refer to the above mention methods.
And Running 1. Starting:
1 ). Before starting up the
pump make sure that the following requirements have been checked and fulfilled.
a). Has the pump been firmly
bolted to the base/foundation?
b) . Have the coupling and
pump unit been aligned as specified?
e). Are the pipes properly
fitted?
d) . Can the unit be easily
rotated by hand at the coupling? (Carry out at least one full rotations)
e). Has lubrication been provided for oil
-lubricated bearings?
2)Before'the pump is started
up, it and the pipes must be vented and filled with the liquid
|