十一、拆卸與裝配
拆卸:
1、關(guān)閉出口閥 2 3 4、松開并拆下密封蓋 5 6、軸承為稀油潤滑的 7、拆下軸承體和軸承托架之間的連接螺栓 8、將軸承體退出凹槽 9、拆下非驅(qū)動端軸承的軸承體 10 11 12 13、從軸套上拆下?lián)跛Γ?span lang=EN-US>
14 15 16 17、松開彈性擋圈 裝配順序按拆卸順序相反進行,但必須注意:
1、安裝轉(zhuǎn)子時必須將軸放穩(wěn),所有的配合螺紋和間隙配合處都必須清洗并涂上裝配粘合劑;
2、裝帶有間隙配合的葉輪時,應注意葉輪的轉(zhuǎn)向;
3、深溝軸承須加熱后裝上軸(軸套);
4、為補嘗泵軸與軸上零件之間由于熱膨脹產(chǎn) |
Ⅺ.
Assembly and Disassembly
1. Close the suction and delivery gate
valves and drain the pump by opening the drain plug;
2. Remove any pipes between additional equipment
and the pump;
3. Remove coupling guard;
4. Loosen and push back the seal cover;
5. Undo flange screws and
release the upper casing half from the lower casing half with the aid of the
forcing screws, remove with lifting gear and store in a safe place.
6. In case of oil-
lubricated pumps, drain off the
oil;
7. Remove the screw
connection between bearing housing and bearing brackets. Also undo the nuts and
bolts which secure the bearing cover;
8. Press the bearing housing out of the
recesses and lift the rotor upwards out of the lower casing half. For further
disassembly, place securely in
horizontal positon.
9. Pull off the bearing
housing of the fixed bearing(opposite the drive end).
10. Undo and twist off the
grooved nut.
11. Remove the deep groove
ball bearing with bush from the shaft.
12. Remove bearing cover.
13. Remove block water ring
from shaft-protecting sleeve;
14. Remove shaft seal
housing;
Pull off shaft protecting sleeve;
15. The impeller located
with sliding fit on the shaft and can normally be removed easily. In case of
difficulty, it can be loosened by
gently tapping with a plastic hammer;
16. Remove second shaft
protection sleeve complete with the shaft seal housing, if fitted. Remove couping half and pull
off deep groove ball bearing;
17. Pull off bearing
housing. Remove circlip and pull off deep groove ball bearing.
Reassembly is effected in
reverse order to; dismantling, but must give your attention to:
1. For assembling the
rotor, position the pump shaft
securely. All fits, threads and sliding fits of the shaft must be cleaned and
coated with assembly paste;
2. Mount the impeller, which has a sliding fit. When fitting
the impeller, observe the direc-
|